Inside the appliance
Induction cooktop main and sub boards. In plain English.
The cooktop main and sub boards are two circuit boards that work together inside the Modernist induction cooktop, with an EEPROM memory chip alongside. The manual prints F0 when the two boards lose contact and F1 when the EEPROM cannot be reached. Restart with POWER, wait with power off, then book a visit.

Where it fits.
Induction cooktop main and sub boards in the appliance
Under the glass of the Modernist induction cooktop. The manual shows no board layout, so we describe no position.
The photo shows the type of component. It cannot tell you which replacement fits your model.
What you notice when this system wants attention.
A Induction cooktop main and sub boards concern can arrive with weaker performance or a code that returns. The component is only blamed after testing.

Dacor induction cooktop will not turn on
A Dacor Modernist induction cooktop that stays off may simply be starting up: the touchscreen takes about a minute to boot. After that, the chart points to the fuse or breaker, then to burner controls set wrongly.

Dacor induction cooktop heats slowly or does not detect the pan
Slow heating or a cooktop that ignores the pan is mostly a cookware match: off-center, wrong size, a base that is not magnetic or flat. Dacor's tables for the Modernist cooktop and the Heritage induction range agree on that.
Owner care, within the model instructions.
Turn off and unplug the appliance before any check you can make yourself. Beware of pooled water and sharp fragments. Never touch a wet plug or live wiring, take off service panels, or go beyond what your model's guide allows.
- 1
Restart with POWER
The table for F0 and F1 starts with a POWER-button restart.
- 2
Disconnect power for 30 seconds
If the code stays, keep the cooktop unpowered for over half a minute at the cord or the breaker panel, then start it.
- 3
Do not open the cooktop
The boards sit under the glass and carry mains voltage. Leave the unit closed and book a visit.
- 4
Note the code and model
Have the code ready, plus the model printed on the rating label.
Cleaning or replacement?
Leave internal testing to a technician.
Book a visit when F0 or F1 returns after the power-off wait.
Book a technician when A2 shows, since the manual links it to a board, wiring or fan blade problem.
Arrange a diagnosticSources and model boundaries.
The Induction cooktop main and sub boards guidance is built on these references. Choose the manual for your own model.
- User Manual, Electric Cooktop DTI36M977BB, DTI30M977BB
Rely on the guide for your precise model. Look at how we research these pages.
What does F0 show on the Modernist induction cooktop?
The Modernist table says the two boards, main and sub, stopped communicating. Restart with POWER, then keep power off for over half a minute if needed.
What is F1 on this cooktop?
F1 is a failed exchange with the EEPROM. The steps match F0: restart with POWER, then keep power off over half a minute.
Can I swap the cooktop board myself?
No. The manual lists no owner repair for either board. Book a visit, naming the code that showed.
Does A2 involve the board?
A2 is the fan motor code. The manual blames a PCB or wiring defect, or a blocked motor blade, for the DC motor not running.
Dacor codes, symptoms, parts, repairs
Link the message to what you do next.
F0
Communication between the main and sub PCBs has failed when F0 shows on the Modernist induction cooktop. Restart with the POWER button, then disconnect power for more than 30 seconds if it continues. Book a visit if it stays.
Dacor induction cooktop will not turn on
A Dacor Modernist induction cooktop that stays off may simply be starting up: the touchscreen takes about a minute to boot. After that, the chart points to the fuse or breaker, then to burner controls set wrongly.
Cooktop repair
Book a diagnostic for your model at the appliance itself.
Find your metro
Office details and the access notes to pass on.